KICKASS® have taken the hassle out of installing an LVD to your 12V system!
Protect your valuable batteries from over-discharge with this simple-to-install system with Anderson style connectors. You no longer have to hardwire an LVD unit into your system.
Once connected, the LVD will allow output power to run your load as normal. The LED status will indicate what state of charge the battery is at while discharging. The device will cut out at 11 Volts which will protect your battery from over-discharge. To reconnect the device, the LVD needs to sense 13 Volts to ensure that the battery has accepted charge before the load is reconnected.
3 WAY SWITCH SETTINGS
NORMAL – The LVD device will disconnect and isolate the load from the battery at 11 Volts. Once the LVD senses 11 Volts, the Low Voltage Alarm will sound for 60 seconds before disconnecting. To reconnect the device once it has been disconnected, the LVD needs to sense 13 Volts before the load will connect to the battery again.
ALARM MUTE – This function is to manually mute the low voltage alarm if required. On this setting the LVD will still operate the same as ‘Normal Mode’ but the low voltage alarm will not sound.
OVERRIDE – This function is to manually override the LVD sensing and will simply connect the battery to the load without the protection of cutting out. This feature should only be used in Emergency situations when required.